Quantcast
Channel: OpenPlant | AutoPLANT Wiki
Viewing all 4857 articles
Browse latest View live

OpenPlant Modeler CONNECT

$
0
0
Current Revision posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Rahul Kumar on 9/10/2019 7:40:26 AM

OpenPlant CONNECT Edition

Work remotely or connected with the market’s most productive and easy-to-use 3D plant design and modeling software

OpenPlant Modeler CONNECT Edition, the first 3D plant modeling software based on ISO 15926, is an accurate, rapid, design engineering solution for 3D plant design. It enhances project teams with mobile information, i-models, and support for multiple formats and data types, such as DGN, DWG, JT, point clouds, and PDF, to provide flexible design and review processes. It is both more versatile and productive than any existing "3-D piping" application. The OpenPlant Modeler CONNECT Edition includes SELECT CONNECTservices, new Azure-based services that provide comprehensive learning, mobility, and collaboration benefits to every Bentley application subscriber Optional Pre-requisite: Structural Synchronizer is required for ISM data interchange workflows only. For information on system requirements, licensing, and what's new in this release, see ReadMe document.

LICENSE USE

 

CONNECT Licensing: This product version utilizes CONNECT Licensing, which is not supported by SELECT activation key(s). CONNECT Licensing features new behavior to enhance your organization’s user administration and security with mandatory user sign-in via CONNECTION Client to access the application. If you are already signed in to the CONNECTION Client, you have met this prerequisite. If you have not, please refer to the Administrator's Resource Center and/or contact your administrator for assistance in the registration and sign-in process. 

Available on Select:-

TECHTALK - New

Visit Bentley Plant Official YouTube Channel - Click below button

 

Like  Subscribe  Share 

FIRESIDE CHAT- New

From Mouth of Product Management - Click Here >>>

www.youtube.com/watch

See Also

OpenPlant Modeler v8i

External Links

Check Videos  ContentLEARN Server

Comments or Corrections?

Bentley Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Tags: OpenPlant Modeler CONNECT edition

OpenPlant Isometrics Manager CONNECT

$
0
0
Current Revision posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Rahul Kumar on 9/10/2019 7:43:26 AM

OPIM CE 

Generate intelligent isometrics from multiple sources

OpenPlant Isometrics Manager CONNECT Edition is the first software to extract intelligent isometric information from any design system’s 3D model, and do so automatically and in real time. It provides management control capabilities for pipe models and isometrics from OpenPlant, Bentley plant products, PDMS, SmartPlant and PDS. OpenPlant Isometrics Manager CONNECT Edition includes SELECT CONNECTservices, new Azure-based services that provide comprehensive learning, mobility, and collaboration benefits to every Bentley application subscriber. For information on system requirements, licensing, and what's new in this release, see the ReadMe document.

LICENSE USE

CONNECT Licensing: This product version utilizes CONNECT Licensing, which is not supported by SELECT activation key(s). CONNECT Licensing features new behavior to enhance your organization’s user administration and security with mandatory user sign-in via CONNECTION Client to access the application. If you are already signed in to the CONNECTION Client, you have met this prerequisite. If you have not, please refer to the Administrator's Resource Center and/or contact your administrator for assistance in the registration and sign-in process.

Available on Select:-

TECHTALK - New

Visit Bentley Plant Official YouTube Channel - Click below button

 

Like Subscribe  Share 

FIRESIDE CHAT- New

From Mouth of Product Management - Click Here >>>

www.youtube.com/watch

See Also

OpenPlant Isometrics Manager v8i

External Links

Check Videos  Content LEARN Server

Comments or Corrections?

Bentley Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Tags: CONNECT Edition, OpenPlant Isometrics Manager CONNECT Edition, OPIM, CE

How to Perform Schema Upgrade From Lower OpenPlant CONNECT Version to Latest OpenPlant CONNECT Version

$
0
0
Revision 1 posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Deepak Singh on 9/10/2019 3:30:24 PM


Applies To 
Product(s):OpenPlant Project Administrator CONNECT Edition
Version(s):

10.05.00.27

Environment: Windows 7/8.1/10 (64-bit)
Area: WorkSpace & WorkSet
Subarea: Schema Upgrade
Original Author:Deepak Singh,Bentley Product Advantage Group

Using OpenPlant Project Administrator CONNECT Edition, requirement is to upgrade schema from OpenPlant CONNECT Edition Update 4 to OpenPlant CONNECT Edition Update 5.

Background

To move from older version of OpenPlant Modeler CONNECT to latest version of OpenPlant Modeler CONNECT, user need to perform schema upgrade ta to make it work properly. Below wiki article explains the procedure regarding schema upgrade.

Steps to Accomplish

  1. Launch OpenPlant Project Administrator CONNECT Edition.



  2. From Configuration ribbon, select desired workset that needs to be upgraded. In this case OpenPlantMetric is considered, refer image below.


  3. From Migration ribbon, select Schema Upgrade tool as shown below.


  4. From Select Source Version window, click on drop down arrow & select Update 4, refer image below.



  5. Once selected, it should reflect like as shown below.



  6. Select OK
  7. To Workset Schema Upgrade dialog, select Analyze option to analyze the schema version. Refer image below.



  8. This will Analyze the schemas of selected workset & pop up window to show User Schema Configurations, refer image below.



  9. Click on OK to proceed. This will show the summary regarding user’s configurations schema changes as shown below.



    Please note that number of user configuration changes will be different based on extent of customization available to workset.
  10. Click on User Configurations tab, notice the defined color coding. Refer image below.



     Shows that new class/property/Relationship has been added

     Shows that new class/property/Relationship has been modified

     Shows that new class/property/Relationship has been modified

  11. Click on Upgrade to perform schema upgrade task.
  12. This will take time based on amount/quantity of customization available to older workset. Refer below image on progress dialog.



  13. Once Analyzing & merging process is successfully carried out, it will pop successfully upgraded message as shown below.



  14. Click on Close to finish the schema upgrade task.



  15. Closing the dialog will pop to perform Restart Click on OK. Refer image below.



  16. Launch OpenPlant Modeler CONNECT Edition with upgraded workset & check its working/functionality.

See Also


Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

Tags: OpenPlant Modeler, OpenPlant Project Administrator CONNECT Edition, Workspace upgrade, Migration from OpenPlant Modeler CE Update 4 to OpenPlant Modeler Update 5, OPPA CE, Update 4 to Update 5, Schema Upgrade, Schema Migration

OpenPlant PID CONNECT

$
0
0
Current Revision posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Rahul Kumar on 9/11/2019 8:20:36 AM

OpenPlant PID CONNECT Edition is built on the ISO 15926 data model, signaling the next step in plant software development. Now, any application that is mapped to the ISO 15926 schema can natively interoperate with OpenPlant PID. This means any data created in OpenPlant PID is available to be shared without the need for complex APIs. OpenPlant PID CONNECT Edition includes SELECT CONNECTservices, new Azure-based services that provide comprehensive learning, mobility, and collaboration benefits to every Bentley application subscriber. For information on system requirements, licensing, and what's new in this release, see the ReadMe document.

LICENSE USE

CONNECT Licensing: This product version utilizes CONNECT Licensing, which is not supported by SELECT activation key(s). CONNECT Licensing features new behavior to enhance your organization’s user administration and security with mandatory user sign-in via CONNECTION Client to access the application. If you are already signed in to the CONNECTION Client, you have met this prerequisite. If you have not, please refer to the Administrator's Resource Center and/or contact your administrator for assistance in the registration and sign-in process.

SUPPORTED OPERATING SYSTEMS - Windows 10 (64-bit), Windows 8.1 (64-bit), Windows 7 (64 bit)

Available on Select -

TECHTALK - New

Visit Bentley Plant Official YouTube Channel - Click below button

 

Like  Subscribe  Share 

FIRESIDE CHAT- New

From Mouth of Product Management - Click Here >>>

www.youtube.com/watch

See Also

OpenPlant PID v8i

External Links

Check Videos content- LEARN Server

Comments or Corrections?

Bentley Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Tags: CONNECT Edition, OpenPlant PID, OPPID, CE

OpenPlant Orthographics Manager CONNECT

$
0
0
Current Revision posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Rahul Kumar on 9/11/2019 8:26:29 AM

Faster, Higher-quality General Arrangement Drawings

OpenPlant Orthographics Manager CONNECT Edition automates the extraction and production of high-quality general arrangement plant drawings from a 3D model. OpenPlant Orthographics Manager can process OpenPlant Modeler, OpenPlant Support Engineering, Integrated Structural Modeling drawings (dgns and i-models), ProStructures drawings and AutoPLANT Modeler i-models; increasing productivity and cost saving in drafting, which allows engineers to focus on their design job. OpenPlant Orthographics Manager CONNECT Edition includes SELECT CONNECTservices, new Azure-based services that provide comprehensive learning, mobility, and collaboration benefits to every Bentley application subscriber. For information on system requirements, licensing, and what's new in this release, see the ReadMe document.

LICENSE USE

CONNECT Licensing: This product version utilizes CONNECT Licensing, which is not supported by SELECT activation key(s). CONNECT Licensing features new behavior to enhance your organization’s user administration and security with mandatory user sign-in via CONNECTION Client to access the application. If you are already signed in to the CONNECTION Client, you have met this prerequisite. If you have not, please refer to the Administrator's Resource Center and/or contact your administrator for assistance in the registration and sign-in process. 

Available on Select:-

TECHTALK - New

Visit Bentley Plant Official YouTube Channel - Click below button

 

Like  Subscribe  Share 

FIRESIDE CHAT- New

From Mouth of Product Management - Click Here >>>

www.youtube.com/watch

See Also

Product TechNotes and FAQs

OpenPlant Orthographics Manager v8i

External Links

Check Videos  Content - LEARN Server

Comments or Corrections?

Bentley Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Tags: OpenPlant Orthographics Manager, OpenPlant Orthographics Manger CONNECT Edition

OpenPlant Support Engineering CONNECT

$
0
0
Current Revision posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Rahul Kumar on 9/11/2019 8:28:34 AM

OpenPlant Support Engineering

OpenPlant Support Engineering CONNECT Edition is an OpenPlant offering that enables engineering, procurement, and construction contractors and owner-operators to accelerate the design, modeling, and placement of plant supports and support assemblies for plant piping, electrical, and HVAC components. The software also includes an extensive catalog supports and support assemblies from a growing number of vendors, increasing the accuracy of supports modeled. OpenPlant Support Engineering quickly creates support models for piping, HVAC, or electrical equipment using pre-defined supports and allows the user to examine multiple support options. Save overall project time by reducing time spent on designing and modeling supports and support assemblies. Users can modify existing supports from OpenPlant Support Engineering’s out-of-the-box catalog to create their own catalog of supports. For information on system requirements, licensing, and what's new in this release, see the ReadMe document.

LICENSE USE

CONNECT Licensing: This product version utilizes CONNECT Licensing, which is not supported by SELECT activation key(s). CONNECT Licensing features new behavior to enhance your organization’s user administration and security with mandatory user sign-in via CONNECTION Client to access the application. If you are already signed in to the CONNECTION Client, you have met this prerequisite. If you have not, please refer to the Administrator's Resource Center and/or contact your administrator for assistance in the registration and sign-in process. 

SUPPORTED OPERATING SYSTEMS - Windows 10 (64-bit), Windows 8.1 (64-bit), Windows 7 (64 bit)

Available on Select -

TECHTALK - New

Visit Bentley Plant Official YouTube Channel - Click below Button

 

Like   Subscribe  Share 

FIRESIDE CHAT- New

From Mouth of Product Management - Click Here >>>

www.youtube.com/watch

See Also

Check - OpenPlant Support Engineering - FAQ's

External Links

Check Video Content -Bentley Learn Server

Comments or Corrections?

Bentley Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Tags: CONNECT Edition, OpenPlant Support Engineering, OPSE, CE

OpenPlant Project Administrator CONNECT

$
0
0
Current Revision posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Rahul Kumar on 9/11/2019 8:30:47 AM

OpenPlant Project Administrator

OpenPlant Project Administrator CONNECT Edition allows users to automate the simple configuration and project setup tasks thereby ensuring that the user is not needlessly exposed to a developer’s tool for schema management when making simple changes that are done at the beginning of every project. It has common tools for all OpenPlant applications including Specification Generator and Reports Editor. Class Editor will still be shipped allowing users to do more complex tasks. For information on system requirements, licensing, and what's new in this release, see the ReadMe document.

LICENSE USE

CONNECT Licensing: This product version utilizes CONNECT Licensing, which is not supported by SELECT activation key(s). CONNECT Licensing features new behavior to enhance your organization’s user administration and security with mandatory user sign-in via CONNECTION Client to access the application. If you are already signed in to the CONNECTION Client, you have met this prerequisite. If you have not, please refer to the Administrator's Resource Center and/or contact your administrator for assistance in the registration and sign-in process. 

SUPPORTED OPERATING SYSTEMS - Windows 10 (64-bit), Windows 8.1 (64-bit), Windows 7 (64 bit)

Available on Select:-

TECHTALK - New

Visit Bentley Plant Official YouTube Channel - Click below button

 

Like  Subscribe  Share 

FIRESIDE CHAT- New

From Mouth of Product Management - Click Here >>>

www.youtube.com/watch

See Also

Product TechNotes and FAQs

OpenPlant Project Administrator

External Links

Check Video Content - Bentley LEARN Server

Comments or Corrections?

Bentley Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Tags: CONNECT Edition, OPPA, CE, OpenPLANT Project Administrator

OpenPlant Product Group Compatibility

$
0
0
Current Revision posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Rahul Kumar on 9/11/2019 2:14:13 PM

Here compatibility across different release versions of OpenPlant Product Group with Operating Systems, ProjectWise and various Database types is presented. The compatibility matrixes are available in pdf format thus could be downloaded.

Follow the link below for instant access to the required matrix:

communities.bentley.com/.../OpenPlant_5F00_Suite_5F00_Compatibility_5F00_Matrix_5F00_tillU4.pdf

Tags: OpenPlant Product Group Compatibility, Product Compatibility Matrix, ProjectWise, Database, Openplant, OpenPlant System Requirements

How to update Pipeline insulation color with single color

$
0
0
Current Revision posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Abhijeet Shinde on 9/16/2019 8:39:08 PM

Applies ToAutoPLANT Modeler
Product(s):AutoPLANT Modeler
Version(s):08.11.XX.XXX
Environment:Windows 7/8.1/10 (64 bit)
Area:Customization
Subarea: 
Original Author:Abhijeet Shinde, Bentley Product Advantage Group

Background

In AutoPLANT Modeler user requirement is to update the pipeline insulation with single color. Below are the steps to achieve the Single Insulation color by layer.

Steps to Accomplish

1.Add new component preference through component preferences.

2.In component Preference Editor search for INSULATION_COLOR, Select and click on OK

3.Change BYLAYER text to GREEN (You can choose color as per your requirement)

4.It will update the insulation color in component preferences.

5.Place Pipe with insulation. It will show insulation color in Green color.


See Also

Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

Tags: Component Preferences, AutoPLANT Modeler, pipe insulation, Insulation Color, bylayer

How to Control Display Style of Element by Creating Rules

$
0
0
Current Revision posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Harshavardhan Kaduru on 9/17/2019 5:51:45 PM


Applies To 
Product(s):OpenPlant Modeler CONNECT Edition
Version(s):

10.05.00.27 Update 5

Environment: Windows 7/8.1/10 (64-bit)
Area: Display Styles
Subarea: -
Original Author:Harshavardhan K, Bentley Product Advantage Group

In OpenPlant Modeler CONNECT Edition, requirement is to define display styles by creating rules.

Background

Sometimes user need to define the display of the elements based of certain criteria as per their requirement which could be based color, style etc. To do this we can use a feature called Display Style

In Display Style, we will define the Display rules of the elements based on our requirement according to select different symbology overrides like line style, line weight, color, transparency.

Below is the illustration for creating the Display Style for pipe, pipe elbow which has WireFrame as Display Style

Steps to Accomplish

  1. Open the Model in OPM CE as shown below.


  2. Click on the VIEW ATTRIBUTES option from the Presentation ribbon.


  3. Once the View Attributes dialog opens, click on the three dots to open DISPLAY STYLES dialog.


  4. Now Click on New at the left corner + button to create new rule, here Pipe_Color(you can edit name of the rule any point of time)



  5. To define rules, click on the icon with small pencil. Once the Display Rules window opens click on NEW to define Display Rule Set from the left corner and name the ruleset as Pipe.



  6. In Condition Editor, click on the pick property you wish to set the rule and once selected click on Symbology overrides under action tab and change display overrides. Illustration below.




    For Example : Select property for pipe, pipe elbow 90 degree and select display style Override as wireframe.

    Click New to Define Display Rule > click on Applies Always > Pick Property > Select the element > Expand Pipe > Miscellaneous and select EC Class Name and click on OK.



    Under action tab click on +Icon to add new action and select Symbology overrides. Click on Edit Symbology overrides (we can select different Symbology overrides like line style, line weight, color, transparency).



    Repeat the same for Pipe Elbow 90 Degree and add Symbology overrides and select WIREFRAME.




  7. Ensure Under Display Rules > Pipe is active as RuleSet and Display Style in Pipe_Color. Close the Display Style window.



  8. Click on Apply Display Style from Presentation ribbon and select the Display style which is created and click on the blank space in the model.

    Verify Results: Illustration of created rule: Pipe_Color 

See Also

Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround.

Tags: OpenPlant Modeler, CONNECT Edition, Control Display, OPM, display sets, connect, display rules

How to Map Pipe Nozzle Properties for use in OpenPlant Isometrics Manager

$
0
0
Revision 14 posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Devendra Warke on 9/18/2019 9:11:14 AM

 In AutoPLANT, “Nozzle” can be placed from piping module. In order to make the properties of piping nozzle available in OPIM, we need to map these properties in the schema.


Review property names in AutoPLANT

In AutoPLANT, you can check the component properties by Double-clicking the respective component.

The most relevant properties to be mapped are the Tag properties (see below) with internal names: TAGNUMBER and TAG.
           


Steps to Follow


A. Map Piping nozzle properties in Schema

  1. Launch Class Editor and open‘OpenPLANT_3D.01.08.ecshema.xml’ from project location.
    Ex: For Default Metric project, C:\ProgramData\Bentley\PlantV8i\BentleyPlantV8iProjects\SAMPLE_METRIC\Config\OpenPlant\schemas.

  2. Expand Classes  >Plant Base Object >Named Item >Device >Piping and Instrument Component > Piping Component>Pipe nozzle
  3. Click on “Properties” tab.
  4. Search "EQUIPMENT_TAG". Then click on ‘Override’ button to override its definition.(If the Property appears in Blue Colour it means that it is already Overridden)

  5. Click Custom Attributes -> Add/Remove.
  6. From the list of Custom Attributes find “AutoPLANT_PDW_Property_MAP”. And Use Down arrow button to add AutoPLANT_PDW_Property_MAP to “Applied custom attributes.” See image below:

  7. Click OK.
  8. A New property map is added to the "EQUIPMENT_TAG" property definition. See image below:


    For “PropertyName” (highlighted above), Type “TAG” (which is the Auto PLANT property which needs to map to Equipment_Tag)
    This same procedure needs to follow for the “NUMBER” property (which needs to map to the AutoPLANT “TAGNUMBER” property
  9. Search “NUMBER” (under properties tab). Then Click on "Override" button to override its definition (If the Property appears in Blue Colour it means that it is already Overridden)
  10. Click Custom Attributes->Add/Remove
  11. From the displayed list find “AutoPLANT_PDW_Property_MAP”

  12. Use Down arrow button to add AutoPLANT_PDW_Property_MAP to “Applied custom attributes.”

  13. Click on OK.
  14. The new property map is added to the “NUMBER” property definition



    For “PropertyName” (highlighted above), Type “TAGNUMBER” (which is the Auto PLANT property to which you want to map Number)

    The Auto PLANT “TAG” property is also mapped to another property in schema: “ORDER_NUMBER”. This appears to create a conflict. Because ORDER_NUMBER is not used in Iso creation process, we need to remove TAG as data source for “ORDER_NUMBER

  15. Search “ORDER_NUMBER” (under properties tab). And click on "Override" button to override its definition.
  16. Remove Property Name value “TAG” from "AutoPLANT_PDW_Property_MAP"& "AutoPLANT_PDW_Catalogue_Property_MAP" attributes.

  17. Save the Schema changes and exit Class Editor.

B. Specify a User Label

To reflect the above schema changes in a connection label for the Pipe Nozzle, the user needs to specify a User label in Open Plant Isometric Configuration Manager. 

  1. Launch Open Plant Isometric Configuration Manager.

  2. Select the respective Isometric style and pick the category “User Labels”.
  3. Click the Green button "+".



  4. Specify label definition as shown below:





  5. Save and Close the configuration manager.



    To verify the results, Create an Isometric from a pipeline that connects to a Pipe Nozzle.
Tags: Bentley OpenPlant Isometrics, Database Mapping

Additional 3D.DWG file Created in OpenPlant Isometrics Manager

$
0
0
Revision 1 posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Abhijeet Shinde on 9/26/2019 7:36:34 PM

Applies To
Product(s):OpenPlant Isometrics Manager
Version(s):08.11.11.XXX (SS6)
Environment:Windows 7/8.1/10 (64 bit)
Area:Settings/Attributes
Subarea: 
Original Author:Abhijeet Shinde, Bentley Product Advantage Group

Problem Description

In OpenPlant Isometrics Manager when user modify the generated Isometric in DGN format and run ISOEXT PUBLISH then the additional 3d dwg file is creating along with dwg file in the same location. See image below

This Wiki article explains procedure on how to stop creating this additional 3d dwg file.

Steps to Resolve

1.Open Project Administrator and select the working project and follow the steps as shown in below snapshot.

 

Note:Select the Isometric style used in the Project

2.In Isometric configuration, Go to Isometric Style > Advanced > Open Seed File as shown in below snapshot.

3.In Seed file, go to Models and delete SheetView as shown in below image.

 

See Also

Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

Tags: DWG File, AutoPLANT, AP-OPIM, OpenPlant Isometrics Manager

How to Add Drawing File to a Project through Relationship Manager

$
0
0
Revision 1 posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Abhijeet Shinde on 9/26/2019 8:11:14 PM

Applies ToAutoPLANT Modeler
Product(s):AutoPLANT Modeler
Version(s):08.11.XX.XXX
Environment:Windows 7/8.1/10 (64 bit)
Area:Relationship Manager
Subarea: 
Original Author:Abhijeet Shinde, Bentley Product Advantage Group

Background

The relationship Manager is an AutoPLANT Modeler application. The Relationship Manager provides a central location for an administrator to manage Bentley AutoPLANT Modeler relationship values (e.g., LineNumber, Unit, Area, Service, Spool, and Document).

 

AutoPLANT supported standalone drawings. These consisted of a drawing file and associated database. Standalone mode has been replaced with briefcase mode, which stores all of the data in the drawing file. Standalone drawings may still be imported into a project.

 

This wiki article describes how to add standalone or briefcase mode drawings to a project.

Steps to Accomplish

1.Click on Bentley Plant V8i icon available on desktop

2.To launch Relationship Manager, go to Project Tools and select Relationship Manager.

3.Select desired project as per requirement.

4.Select Drawing File to add, the following dialog will displays

5.You can also drag and drop a document from Windows File Explorer onto the Relationship Manager interface to add the document.

6.You can add drawings to the project from the Project from the drawings source location.

7.Select the target location field. Select the target location and click OK. For e.g. for Piping Drawing file PIPE_DWG selected.

8.Click Add button to add Drawing File to project.

Note:Set the Overwrite option to overwrite a drawing of the same name that exists in the target location.

9.Expand a folder to display its drawing file.

 

See Also

Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

Tags: AutoPLANT Modeler, Relationship Manager, Add Drawing File, AutoPLANT Piping

How to Manage Gasket Tick Appearance in Dimension for OpenPlant Isometrics Manager CE

$
0
0
Revision 1 posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Abhijeet Shinde on 9/26/2019 8:31:22 PM

Applies To
Product(s):OpenPlant Isometrics Manager
Version(s):CONNECT Edition
Environment:Windows 7/8.1/10 (64 bit)
Area:Settings/Attributes
Subarea: 
Original Author:Abhijeet Shinde, Bentley Product Advantage Group

Problem Description

When user upgrading APM V8i to AP_OPIM CE the gasket tick are not appearing after doing customization in Style.cfg file for Isometric style. They do appear correctly if user change the isometric style to the default IFC isometric style.

This Wiki article explains procedure on how to remove L shape gasket tick from the dimension

Steps to Accomplish

1. Open the Style.cfg file from the location and do the changes as shown in below image.

C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant\Isometrics\styles\IFC\config 

2.Gasket Tick is appearing in L shape, it should appear separately as dotted line.

3.Open Project Administrator, select the working Project > select relevant style > click on update to launch Isometric configuration as shown in below image.

4.Click on Seed file 

5.In OpenPlant Isometrics Manager, Select Drawing > Annotate > click on Dimension Styles as shown in below image.

6.In Dimension Style, Select Text tab and change Font to 1 WORKING font as shown in below image.

7.The Gasket tick is now appearing in dimension properly.


See Also

Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

Tags: CONNECT Edition, Settings/Attributes, Gasket Tick, OpenPlant Isometrics Manager

How to Assign Pipe Insulation Properties for All Insulated Components in Model

$
0
0
Revision 1 posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Devendra Warke on 9/27/2019 7:07:06 AM

 Product(s):

AutoPLANT Modeler

 Version(s):08.11.14.124
 Environment:Windows 7,8.1,10 (64 bit)
 Area:Modeling
 Subarea:Insulation Color
Original Author:Devendra Warke

Background

Pipe Insulation is one of the primary attributes that the user would like to modify. The article sheds light over how we can set numerous attributes relating to Pipe Insulation like Insulation Colour, Insulation Thickness, Insulation Layer, Insulation Line Style:etc.

These settings when done will be applicable on project level which will be populated throughout the project.

How to Accomplish

1. Browse to location for the respective Project: -
 
    Default Location for the Project - C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_IMPERIAL\Config

2. Open “config.ini” file present in that location.

    

3. Find “INSULATION”

     

 Once you find these, we can see that we have different variables for Insulation Thickness, Insulation Spec, Insulation Layer, Colour and Line Style. We can edit the default values and set the values as per our         requirements.
 Check the below image: - 

  

  These Syntaxes will be present in “[Piping.SysPaths] “section: - 

   

4. Save and close “config.ini” file.
    By performing this, we can set the Insulation thickness, colour, spec and line style for the Insulation of the Pipe throughout the project.

    
     

See Also

Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section.
THANK YOU!



    

Tags: insulation, AutoPLANT Modeler, property, Insulation Thickness, Insulation Color, Settings, how to, Customization, AutoPLANT Piping

How to use Format Specifier in OpenPlant Isometrics Manager

$
0
0
Revision 5 posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Rahul Kumar on 9/29/2019 7:27:42 AM

Applies To
Product(s):OpenPlant Isometrics Manager
Version(s):08.11.11.XXX (SS6)
Environment:Windows 7/8.1/10 (64 bit) & Others
Area:Settings/Attributes
Subarea:Format Specifier- Isometric report
Original Author:Rahul Kumar, Bentley Product Advantage Group

To Discuss various Format specifier to be used in OpenPlant Isometrics Manager. 

Background

In OpenPlant Isometrics Manager, various properties/attributes requires a unique format to display in isometrics drawing. Below are few case which help user to assign properties with specific format.  It can be experienced using both OpenPlant modeler and AutoPlant Modeler. This has been shown in context with OpenPlant Modeler and OpenPlant Isometrics Manager. However similar approach could be utilized for AutoPLANT modeler and OpenPlant Isometrics Manager, with checking the style folder with different storage paths. Many values are specified in decimal inches, that are required to display it in Feet-Inch-Fraction format. Below example will show it for Olets here.

The different display output formats for a single property make it difficult to use a global format configuration. Therefore a method has been designed to directly specify the display format when the property in question is referenced. In OpenPlant Isometrics Manager a component property is referenced in one of two ways depending on the use scenario

  • $(<property name>)
  • <Property name>

Internally each property is stored as a string and with the above references a trimmed string is output. A format specifier can be added to the property name separated by a colon.

<property name>:<format specifier>

The specifier character defines how the property is interpreted;



[flags][width][.precision]specifier

The sub specifier flags, width and precision are optional and follow these conventions.

See Examples below

Example: the property SHEETNO = 2 can be formatted as integer

Example: the property angle = 89.250089 can be output as

Example: the property LENGTH = 31.675 can be output as

Example: the property CM1 = BW can be formatted as string

Steps to Accomplish

  1. Launch OpenPlant Isometrics Manager.
  2. Select Project unit, say OPModeler_Imperial here and click OK.
  3. Click on ‘Configuration’ Icon to launch Isometric configuration dialog box.



  4. From Isometric configuration dialog box, select “User Labels”. Check Olet defined here.
    Text used here as : $(SIZE2)” x $(SIZE1)”



  5. Check Isometrics Below.  Some property displays in decimal even after implementation of IMPERIAL Format through style.cfg file.



  6. Change text as per image shown below.
    Text : $(SIZE2) x $(SIZE1:I)



    Note –
    User can also try specifier F for Feet-Inch-Fraction display.

  7. Save labels and check result. 

See Also

User can also check Display Format Specifer topic from help file menu.

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

Tags: User Labels, OPIM, Format Specifier, OpenPlant Isometrics Manager

How to Delete a Drawing File through Relationship Manager in AutoPLANT Modeler

$
0
0
Current Revision posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Abhijeet Shinde on 9/30/2019 6:23:59 PM

Applies To
Product(s):AutoPLANT Modeler SS8
Version(s):08.11.13.XXX
Environment:Windows 7/8.1/10 (64 bit)
Area:Relationship Manager
Subarea: 
Original Author:Abhijeet Shinde, Bentley Product Advantage Group

Background

The relationship Manager is an AutoPLANT Modeler application. The Relationship Manager provides a central location for an administrator to manage Bentley AutoPLANT Modeler relationship values (e.g., LineNumber, Unit, Area, Service, Spool, and Document).

The Relationship Manager is used to delete Drawing File in a Project Environment. Deleting a Drawing File deletes its associated component records and relationships from the project.

This wiki article describes how to Delete a Drawing File from through Relationship Manager in AutoPLANT Modeler.

Steps to Accomplish

1. Click on Bentley Plant V8i icon available on desktop

2.To launch Relationship Manager, go to Project Tools and select Relationship Manager.

3.Select desired project as per requirement.

4.Expand a Document folder to see available Drawing Files

5.Select Drawing File and do right click. Select Delete Option to delete Drawing File.

6.The following dialog will display.

Note:If you wish to store backup of the drawing file in the Recycle Bin folder prior to deletion then select Backup First option.

7.The document is moved to the Recycled Bin folder.

See Also

Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

Tags: AutoPLANT Modeler, Relationship Manager, AutoPLANT, DELETE DRAWING FILE

How to open generated DGN isometrics Drawing in CONNECT Edition

$
0
0
Revision 1 posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Vidit Ruhela on 9/30/2019 6:26:02 PM



  
 Applies To 
  
 Product(s):AutoPLANT Modeler/OpenPlant Isometrics Manager
 Version(s):10.XX.XX.XXX
 Environment: Windows 7 / 8/10 (32/64 bit)
 Area: Open/Save - OpenPlant Isometrics Manager for AutoPLANT
 Subarea: 
 Original Author:Vidit Ruhela, Bentley Product Advantage Group
  

Overview

How to open generated DGN isometrics Drawing in CONNECT Edition.

Steps to Accomplish:

  1. Now generated isometrics drawing (DGN) can be directly opened by Right click the specified Drawing.

  2. Once the drawing file opened in OpenPlant Isometrics manager CONNECT Edition user can even modify the labels and can show COMPONENT Data.




See Also:

https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40416/openplant-isometrics-manager-for-autoplant

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Tags: CONNECT Edition, AutoPLANT Modeler, Seed File, OpenPlant Isometrics Manager

How to open Seed File in AutoPLANT-OpenPlant Isometrics CONNECT Edition

$
0
0
Current Revision posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Vidit Ruhela on 9/30/2019 7:02:36 PM



  
 Applies To 
  
 Product(s):AutoPLANT Modeler/OpenPlant Isometrics Manager
 Version(s):10.XX.XX.XXX
 Environment: Windows 7 / 8/10 (32/64 bit)
 Area: Open/Save - OpenPlant Isometrics Manager for AutoPLANT
 Subarea: 
 Original Author:Vidit Ruhela, Bentley Product Advantage Group
  

Overview

How to open Seed File in OpenPlant Isometrics Manager for AutoPLANT CONNECT Edition.

Steps to Accomplish:

  1. Open AutoPLANT Project Administrator, select Project and click on Update as shown in below screenshot.



  2. Select Style and then as shown in below screenshot directly open Seed File mentioned in step 6.



  3. Now Seed File can be directly opened through OpenPlant Isometrics Configuration UI.

See Also:

https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40416/openplant-isometrics-manager-for-autoplant

 

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Tags: CONNECT Edition, AutoPLANT Modeler, Seed File, OpenPlant Isometrics Manager

How to Import a Drawing File from one Project to another Project using Relationship Manager

$
0
0
Revision 1 posted to AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki by Abhijeet Shinde on 9/30/2019 7:05:17 PM

Applies To
Product(s):AutoPLANT Modeler SS8
Version(s):08.11.13.XXX
Environment:Windows 7/8.1/10 (64 bit)
Area:Relationship Manager
Subarea: 
Original Author:Abhijeet Shinde, Bentley Product Advantage Group

Background

The relationship Manager is an AutoPLANT Modeler application. The Relationship Manager provides a central location for an administrator to manage Bentley AutoPLANT Modeler relationship values (e.g., LineNumber, Unit, Area, Service, Spool, and Document).

In Project sometimes there are certain requirements to import drawing files from one Project to another Project of the same Unit.

This Wiki article describes the steps on how to Import the Drawing Files from one Project to another Project using Relationship Manager.

Steps to Accomplish

1. Click on Bentley Plant V8i icon available on desktop.

2.To launch Relationship Manager, go to Project Tools and select Relationship Manager.

3.Select desired project as per requirement.

4.Go to Tools > Document Tools > Import > From Project

5.Select the Project that contains the Drawing Files to Import.

6.Use the arrow buttons between the Project, select Drawing File to import into the Project and Click OK.

7.The following dialog display

8.Select the target location and click OK. For e.g. for Piping Drawing file PIPE_DWG selected.

9.Click on Import button to Import the Drawing File from one Project to Another Project.

See Also

Still a Problem?

If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

Tags: AutoPLANT Modeler, Relationship Manager, AutoPlant V8i, Import Drawing File
Viewing all 4857 articles